CA – power contactors for AC applicationsCH1130 – compact contactor for AC and DC (semi-bidirectional) up to 4.8 kV
CA – power contactors for AC applicationsContactorsRequest
2833bookmark
CH1130 – compact contactor for AC and DC (semi-bidirectional) up to 4.8 kVContactorsRequest
4614bookmark
Series 3 pole: CA1315/04, CA1330/08
1 pole: CA1115/04, CA1130/08
CH1130
Type of voltage AC (f ≤ 400 Hz) DC (semi bidirectional), AC (f < 60 Hz)
Main contacts, configuration CA1315/04, CA1330/08: 3 x NO
CA1115/04, CA1130/08: 1 x NO
1x SPST-NO
Nominal voltage Un CA1315, C1115: 1,500 V
CA1330, CA1130: 3,000 V
3,000 V
Rated operating voltage Ue CA1315, C1115: 1,800 V
CA1330, C1130: 3,600 V
3,600 V
Rated insulation voltage Ui CA1315, C1115: 2,000 V
CA1330, C1130: 4,800 V
Rated impulse withstand voltage Uimp CA1315, C1115: 15 kV
CA1330, C1130: 25 kV
Conv. thermal current Ith CA1xxx/04: 350 A, 540 A
CA1xxx/08: 800 A
250 A
Rated short-time withstand current Icw Upon request, optimized for switching off 400 Hz
Short-circuit breaking capacity Upon request, optimized for switching off 400 Hz
Rated short-time withstand current Icw Upon request, optimized for switching off 400 Hz
Contact material main contacts AgSnO2
Aux. contact 1x  S870 (a1), 1x  S870 (b0), 2x  S826 or 
4x  S826 or
2x  S970 (a1), 2x  S970 (b0) or
1x  S970 (a1), 1x  S970 (b0)
2x S826, silver, DC13/110 V: 0.2 A, 24 V: 2 A
Coil voltage Us 24, 36, 48, 72, 110 V 24 / 36 / 72 / 110 V DC
Coil tolerance -30% ... +25% Us –30 % … +25 % Us
Coil power consumption 100 W/75 W and 280 W/27 W resp. cold/warm
IP rating (IEC 60529) IP00
Mechanical endurance > 500.000 operating cycles >2 million operating cycles
Vibration / Shock (IEC 61373) Category 1, Class B Class B, Category 1
Mounting orientation any horizontal / vertical
Temperature range -40 °C ... +70 °C –40 °C… +70 °C
Storage temperature -40 °C ... +85 °C
Weight CA1315/04: 20 kg
CA1130/08: 25 kg