CPP – Compact single-pole NO and NC contactorsCU – Double-pole DC power contactor
CPP – Compact single-pole NO and NC contactorsContactorsRequest
5795bookmark
CU – Double-pole DC power contactorContactorsRequest
2733bookmark
Type of voltage, main contacts, configuration
Type of voltage DC, uni-directional / AC,f ≤ 60Hz DC (unidirectional)
Main contacts, configuration CPP1115-02: 1 NO
CPP2115-011: NC
2 x NO
Electrical data according to IEC 60077-2
Nominal voltage Un 1,500 V 1,500 V
Rated insulation voltage UNm 3,000V @ PD3, OV3
3,600V @ PD2, OV2
Rated impulse withstand voltage UNi 15 kV
Pollution degree
Overvoltage category
PD3 or PD2
OV3 or OV2 (see UNm)
Conv. thermal current Ith CPP1115-02: 200 A @ 120 mm2, 70° C
CPP2115-01: 120 A @ 35 mm2, 70° C
1000 A
Rated operating current Ie CPP1115-02: 200 A
CPP2115-01: 120 A
Component category B
Breaking capacity see catalogue
Rated short-circuit making capacity Icm CPP1115-02: 2,000 A @ L/R = 0 ms
CPP2115-01: 850 A @ L/R = 0 ms
Rated short-time withstand current Icw CPP1115-02: 2,000 A @ t < 0.1 s
CPP2115-01: 1,800 A @ t < 0.1 s
Critical current range None
Electrical data according to DIN EN IEC/UL 60947-4-1, GB/T 14048.4
Rated operating voltage Ue 1,500 V 1,800 V
Rated insulation voltage Ui 1,500 V 3 kV
Rated impulse withstand voltage Uimp 8 kV 15 kV
Pollution degree
Overvoltage category
PD3
OV3
Conv. thermal current Ith CPP1115-02: 160 A @ 50 mm², Ta = 70° C
CPP2115-01: 50 A @ 10 mm², Ta = 70° C
1000 A
Rated short-time withstand current Icw CPP1115-02: 2,000 A
CPP2115-01: 1,800 A
e.g. 2 x 450 A fuse (type gPV) connected in parallel
Aux. switches,magnetic drive, general data
Auxiliary switches 2x Change over (SPDT)
Snap-action switch S870
Contact material silver or gold
Coil voltage Us 24 / 36 / 48 / 60 / 72 / 84 / 96 / 110 V DC
24, 36, 72, 110 V DC
Coil tolerance 30 % ... +25 % -10% ... +10%
Coil suppression Suppressor diode
Temperature range -40° C ... +70° C -40 °C ... +70 °C
Mounting orientation horizontal, vertical horizontal/vertical
Mechanical endurance 2,000,000 operations 2 million operating cycles