1-pole DC bidirectional relay,
Contact system SPST-CO
The compact high-voltage relay R400 has been specially developed for use in test systems. Used there, the relays are required for testing electrical safety. The switching devices isolate all non-active components during the high-voltage and insulation test procedure. As part of the protective conductor test, they switch currents up to a maximum of 25 amps to the test object.
Another area of application for the small switching device is its use as a precharging relay. This is because the relay is particularly advantageous in smaller traction applications or applications with traction batteries when only low precharging currents need to be switched.
Type of voltage | DC bi-directional |
Main contacts, configuration | R411: SPST-NO, 1 pole R412: SPST-NO, 2 pole R431: SPST-CO, 1 pole R432: SPST-CO, 2 pole |
Nominal voltage Un | 1,500 V |
Rated operating voltage Ue | 1,500 V |
Rated insulation voltage Ui | 1,500 V |
Rated impulse withstand voltage Uimp | 10 kV |
Pollution degreeOvervoltage category | PD2 OV2 |
Conv. thermal current Ith | 25 A @ 4 mm² min. Higher currents on request |
Rated short-time withstand current Icw | 200 A @ t = 20 ms |
Control voltage Us | 24 V DC @ 0 ... 40° C |
Coil tolerance | –10 ... +10 % Us, Preliminary data |
Coil suppression | Electronic coil controller, PWM module |
Vibration / Shock (IEC 61373) | Category 1 / class B, In preparation |
Mechanical endurance | 3.000.000 operating cycles |
Mounting orientation | horizontal, vertical (do not mount upside down) |
Temperature range | 0° C ... +40° C |
Weight | 1 pole: 260 g 2 pole: 350 g |