C195 – AC and bidirectional DC ContactorC295 – double pole contactors for DC or AC
C195 – AC and bidirectional DC ContactorContactorsRequest
876bookmark
C295 – double pole contactors for DC or ACContactorsRequest
877bookmark
Series C195 X/ A/, B/, S/, T/, W/ C295 A, B, K, L, S, T
Type of voltage DC bidirectional, DC unidirectionalAC DC, AC
Main contacts, configuration 1 x NO / 1 x SPDT 2 x NO
Nominal voltage Un 200 V / 1,000 V / 1,500 V 200/750/1.200 V
Rated insulation voltage Ui 600 V / 1,200 V / 1,800 V 1,000/1,600 V
Pollution degree
Overvoltage category
PD3 / OV3
Rated impulse withstand voltage Uimp 6 kV / 8 kV / 10 kV 8/10 kV
Conv. thermal current Ith NO: 320 A / 250 A NC: 160 A 120 A
Rated short-time withstand current Icw NO: 2.300 A NC: 1.000 A
Breaking capacity Depending on the configuration 1,000 V DC, L/R 1 ms: 90 A; L/R 15 ms: 25 A
Aux. contact 1x or 2 x SPDT (snap switch S870) 2 x snap switch S870, SPDT, optional
Coil voltage Us 24, 36, 48, 60, 72, 80, 96, 110 V DC 24, 36, 48, 60, 72, 96, 110, 220 V DC
Coil tolerance -30% ... +25% at 70° C max. -40% ... 0% at 40° C max. -30% ... +25%
Mounting orientation horizontal, vertical exception: do not mount upside down
IP rating (IEC 60529) IP00 IP20, terminals and lower baffle IP00
Temperature range Industry: -25 °C ... +50 °C Railway: -40 °C ... +70 °C -25 °C ... +70 °C
Mechanical endurance >3 million op. cycles (standard coil) 100,000 op. cycles (bistable coil) > 3 million operating cycles