CT – AC and bi-directional DC power contactorCA – power contactors for AC applications
CT – AC and bi-directional DC power contactorContactorsRequest
4996bookmark
CA – power contactors for AC applicationsContactorsRequest
2833bookmark
Series CT 3 pole: CA1315/04, CA1330/08
1 pole: CA1115/04, CA1130/08
Type of voltage DC (bidirectional), AC (f < 60 Hz) AC (f ≤ 400 Hz)
Main contacts, configuration 1 x SPST-NO or 2 x SPST-NO CA1315/04, CA1330/08: 3 x NO
CA1115/04, CA1130/08: 1 x NO
Nominal voltage Un 1,500 V or 3,000 V CA1315, C1115: 1,500 V
CA1330, CA1130: 3,000 V
Rated operating voltage Ue 1,800 V or 3,600 V CA1315, C1115: 1,800 V
CA1330, C1130: 3,600 V
Rated insulation voltage UNm 3,000 V or 4,800 V
Rated impulse withstand voltage UNi 15 kV or 30 kV
Pollution degree
Overvoltage category
PD3 / OV3
Conv. thermal current Ith 400A, 800A oder 1,100A CA1xxx/04: 350 A, 540 A
CA1xxx/08: 800 A
Component category A2
Rated short-time withstand current Icw series-specific, see catalogue Upon request, optimized for switching off 400 Hz
Contact material main contacts AgSnO2 AgSnO2
Aux. contact 1x S870 (a1), 1x S870 (b0), 2x S826 or 4x S826 1x  S870 (a1), 1x  S870 (b0), 2x  S826 or 
4x  S826 or
2x  S970 (a1), 2x  S970 (b0) or
1x  S970 (a1), 1x  S970 (b0)
Coil voltage Us 24, 36, 72, 110 V DC 24, 36, 48, 72, 110 V
Coil tolerance -30% ... +25% -30% ... +25% Us
Coil power consumption series-specific, see catalogue 100 W/75 W and 280 W/27 W resp. cold/warm
Coil suppression Suppressor diode / double coil controller (DCC)
Mechanical endurance series-specific: 300.000 min. / 2.000.000 max. operating cycles > 500.000 operating cycles
Vibration / Shock (IEC 61373) Category 1, class B Category 1, Class B
Mounting orientation horizontal / vertical any
IP rating (IEC 60529) IP00 IP00
Temperature range -40 °C ... +70 °C -40 °C ... +70 °C
Storage temperature -40 °C ... +85 °C -40 °C ... +85 °C
Weight series-specific, see catalogue CA1315/04: 20 kg
CA1130/08: 25 kg