PAD10 – Passenger alarm devices for lintel mounting | PAD40 – Passenger alarm devices for wall mounting | |
Series | PAD10 series | PAD40 series |
Mechanical endurance | > 1,000 operations | > 1,000 operations |
Actuation travel | approx. 15 mm | approx. 16 mm |
Actuating force | 65 N ... 120 N (not lead sealed) | 65 N ... 120 N (not lead sealed) |
Can be lead sealed | Yes | Yes |
Reset | Square spanner and spring return, optional | DB square key Triangular wrench key, USA Triangular wrench key 6.5 CNOMO Type 1 Spring reset optional |
Nominal voltage Un | 150 V | 150 V |
Rated insulation voltage Ui | 250 V | 250 V |
Conv. thermal current Ith | 3 A | S870: 3 A S826: 10 A |
Switching element | 2x snap-action switches S870, SPDT | 3 x snap-action switches S870, SPDT 2 x snap-action switches S826, SPDT-DB |
Contact material | Silver (Ag90Ni10) or gold (AuNi3Ag26) | Silver (Ag90Ni10) or gold (AuNi3Ag26) |
Ingress protection rating, IEC 60529 |
Front panel, not operated: IP42 Rear panel: IP00 | Front panel, not operated: IP42 Rear panel: IP00 |
Vibration, Shock | Category 1, Class B | Category 1, Class B |
Mounting orientation | Lintel mount: Handle pointing downwards | Wall mount: Handle pointing downwards |
Temperature range | -20 °C ... +70 °C | -40 °C ... +70 °C |