Switchgear for rolling stock
The switches of series SD, SE, SDE and SCO have a modular design and can be used for the function disconnect, earthing, disconnect and earthing as well as switching between two circuits (change-over).
The SCO2, SCO3 and SCO4 HV changeover units come in series of 2, 3, and 4 position assemblies. They are manually operated or driven by a linear or geared motor. Multipole and of modular design, they sport up to 10 rotating switching chambers fitted with 8 contacts and one or two knives each.
The rotary scissor switches are designed for off-load adjustment of electrical configurations, especially of multi-system locomotives, but also as reliable HV disconnectors for the power converters and traction motors of electric railway vehicles.
Input voltage range to UIC 550 | 600 ... 3,000 V AC, 16 2/3 ... 50 Hz 600 ... 3,000 V DC (5.000 V DC nach UIC550) |
Conv. thermal current Ith | 500 A |
Control voltage US | Manual operation: --- Linear motor: 24 V Gear motor: 110 V |
Ingress protection rating, IEC 60529 | IP00 |
Temperature range | - 25 °C ... + 85 °C |
Standards | EN 50124, IEC 60077, IEC 61373, UIC 550 |