The CVB Series vacuum circuit breaker is the main electrical switch and protection device of AC locomotives and electric multiple units.
Mode of operation: The energy required to switch on the CVB is stored by a spring. As soon as the switch-on signal is applied, the main spring release latch is unlocked and the switching operation is triggered. After that the spring gets recharged in less than 10 s. The signal “Hold” will keep the CVB in its switched-on position. The vacuum circuit breaker is switched off when the signal “Hold” is cancelled or the control voltage supply is lost – the spring remains charged and ready for the next switching operation.
CVB 15/08 R 110E-00
CVB 15/08 × 110E-00 001
By selecting this option you finish the configuration.
Nominal voltage | 15 kV AC, 16 2/3 Hz |
Rated operating voltage Ue | 17.5 kV AC |
Rated operating current | 800 A |
Short-circuit breaking capacity | 25 kA |
Utilization category | C3 |
Control voltage US | 24/50/72/110 V DC |
Temperature range | -40 °C ... +70 °C (tested up to -50 °C) |
Standards | IEC 60077-4, EN 50124-1, EN 60694, EN 50155, EN 50121-3-2 |