CH715, CH815 – Contactors up to 3,000 V for rail

Single-pole NO contactors for AC and DC (unidirectional). Rated insulation voltage 3,000 V; conventional thermal current 50 A.

CH815 Contactor up to 3 kV DC and 1.5 kV AC with attached electric arc chamber and S800 snap-action switch as auxiliary contact.

The CH715 and CH815 series have been designed for a nominal switching capacity of 16 kW (AC and DC). They are used for the activation of power supply systems and as a main and auxiliary contact of heating registers in heating and air-conditioning systems. The electric arc is extinguished in the attached electric arc chamber.

Features

Unidirectional switching of up to 3,000 V DC

The DC design boasts blowout magnets which drive the electric arc to the attached arcing chambers.

Switchgear in rail carriages
  • Activation contactor of power supply systems
  • Main and auxiliary contactor of heat registers in heating and air-conditioning systems
Auxiliary contact for CH815: Snap-action switch with positive opening operation

The design of the CH815 boasts an S800-series snap-action switch which reports the state of the main contacts reliably to the higher-level control system.

Ambient temperatures: –50°C to +70°C

Due to their approval for rail applications, the contactors can also be used in extreme temperatures.

Specifications

CH715-CH815
Type of voltageDC, AC
Main contacts, configuration1 x NO
Nominal voltage Un3 kV DC, 1.5 kV AC
Rated insulation voltage Ui3 kV
Test voltage at 50 Hz for 10 s10 kV
Rated switching capacity atU = 3,000 V DC5 A L/R = 1 ms
Rated switching capacity atU = 1,500 V AC 50 Hz10 A cos φ = 1.0
Switching cycles per hour(under rated load)120/h
Max. breaking capacity atU = 3,000 V DC30 A L/R = 0 ms
Conv. thermal current Ith50 A
Aux. contactCH815: 1 x SPDT
Coil voltage Us24, 36, 110, 120 V DC
Coil tolerance-30% ... +25%
IP rating (IEC 60529)IP00
Mechanical endurance1 million operating cycles
Temperature range-25 °C ... +70 °C
Storage temperature-40 °C ... +80 °C
Weightapprox. 3,300
Show all data

Related Downloads

Catalogue F170
CH715, CH815, CH500, CH800, CH801, CH1030 - 1 pole HV contactors for voltages up to 3 kV DC/AC
Safety instructions contactors
AFS / C100 / C110B / C130 / C137 / C152...C159 / C160 / C162 / C163 / C164 / C165 / C193 / C195 / C294 / C295 / C160 / C3xx / C8xx / C400 / C600 / CA / CF / CH / CL / CP / CPP / CS / CT / CU / S100/80 / S132 / S134 / S135 / S005 / S007 / S008 / S306 / S307 / S310
/en/products/contactors/thank-you/CH715, CH815 – 3 kV contactorsContactors

Your quick contact to us!

If you have any questions, suggestions or other concerns, please let us know. Please fill out our short contact form.