C360 – AC and bi-directional DC contactors up to 1,500 volts for railway applications

Compact single-pole NO contactors for AC and DC (bi-directional) up to 1,500 volts rated insulation voltage. Making current up to 2,500 amps; conventional thermal current up to 500 amps; short-time current up to 3,000 amps

C360K/500 Ui up to 1,500 V, Ith = 500 A.
Design with blowout magnets and large extinguishing chamber for a particularly high breaking capacity.
C360K/300 Ui up to 1,500 V, Ith = 300 A.
Design with blowout magnets and large extinguishing chamber for a particularly high breaking capacity.
C360A/500 Ui up to 1,500 V, Ith = 500 A.
Design with blowout magnets, arcing chamber and cover.
C360A/300 Ui up to 1,500 V, Ith = 300 A.
Design with blowout magnets, arcing chamber and cover.
C360S/500 Ue = 60 V, Ith = 500 A.
Main contact system w/o arc chamber.
C360S/300 Ue = 60 V, Ith = 300 A.
Main contact system w/o arc chamber.

The bi-directional DC contactors of the C360 series switch high powers in a small space. With a making capacity of up to 2,500 amps, the compact switchgear is suitable for applications with high inrush current or high capacities.

All versions can continuously conduct up to 500 amps. In the event of a short circuit, 3,000 amps, can even flow for one second without the contacts welding. The contactor therefore maintains its full function in order to disconnect high power ranges if necessary up to 500 amps and up to 1,500 volts – irrespective of the current direction. The full bidirectionality is important for many applications in railway vehicles. Many design variants are also available, matched to a wide range of applications, e.g. as the main contactor in traction and auxiliary converters of battery and hybrid vehicles or as an isolating contactor in battery circuits with high currents.

Features

Compact dimensions – high rated insulation voltage Ui up to 1,500 volts

Small dimensions – big performance! Nevertheless, all the air gaps in the contact area have been generously dimensioned. The rated insulation voltage is 1,500 volts. The arc chamber of the C360 is made of plastic. This is efficient and saves weight.

Making capacity Icm up to 2,500 A, bistable design available

The C360 can switch on a current of up to 2,500 A (monostable design in a horizontal installation position; L/R = 0 ms).

A PWM controller regulates the coil current and ensures low-bounce switch-on as well as a low and constant holding power. High contact forces and solid silver contacts benefit the making capacity.
High conventional thermal current Ith up to 500 A

All versions of the C360 can continuously carry up to 500 A. (Cross-section of the connections: 185 mm2, maximum ambient temperature: 85°C; terminal heating: +65 kelvin). The value is reached through very high contact forces.

High short-time current-carrying capacity Icw up to 3,000 A (1 s)

The C360 can carry a current of up to 3,000 A for one second without the contacts welding. This is enough time for the short circuit fuse to trip. The short-time withstand current rating is based on high contact forces and optimised silver contacts.

Full bidirectionality – reliable disconnection of high performances

All versions of the C360 can reliably disconnect high currents and voltages, irrespective of the current direction.

These properties are achieved in the A and K versions through the special arrangement of blowout magnets and arcing chambers, high contact forces and generously dimensioned clearances in the contact aera.

Use as the main contactor in traction and auxiliary converters of battery and hybrid vehicles or as an disconnector in battery circuits with high currents
Traction contactor for battery or hybrid vehicles:
  • Main contactor in combination with a precharging contactor in the traction converter of locomotives, railcars and trams
Contactor for auxiliary converter for battery or hybrid vehicles:
  • Main contactor in combination with a precharging contactor in the auxiliary converter of locomotives, railcars and trams
Disconnecting contactor in battery circuits:
  • Disconnecting contactor for battery-powered functions in locomotives and multiple units
  • Contactor for battery-powered functions in passenger coaches
  • Deep discharge protection for batteries in emergency power supplies
Auxiliary switch with mirror contact function

Series C360 contactors are equipped with auxiliary contacts with mirror contact function. The mirror contact function complies with the standard DIN EN 60947-4-1 Annex F.
The mirror contact function means that the NC contact of the auxiliary contact must not be closed at the same time as the NO main contact.

Specifications

C360K, C360A, C360S
Type of voltageDC bidirectional, AC (f ≤ 60 Hz)
Main contacts, configuration1 NO
Rated operating voltage UeC360K: 1,000 V @ PD3 / 1,500 V @ PD2
C360A: 1,000 V @ PD3 / 1,500 V @ PD2
C360S: 60 V @ PD3
Rated insulation voltage Ui1,000 V @ PD3
1,500 V @ PD2
Pollution degree
Overvoltage category
PD2 or PD3, see Ue and Ui
OV3
Rated impulse withstand voltage Uimp10 kV
Conv. thermal current Ith500A @ 40° C
300 A @ 70° C
150 A @ 70° C
Breaking capacity150 A @ Ie (L/R = 1 ms) DC, Ue= 900 V
420 A @ Ie (cosφ = 0.8) AC, Ue= 900 V
Auxiliary switches2x SPDT max. with mirror contact function, single-break
Snap-action switches S880: AC-15: 230 VAC/1.0 A; DC-13: 60 VDC/0.5 A
Coil voltage UsStandard:
12...24 V DC (operating range 9.5...36 V DC) / 48 V DC (operating range 33.6...60 V DC)
Bistable:
24 / 48 V DC
Mounting orientationhorizontal, vertical
(do not mount upside down)
Temperature range-40° C ... +85° C
Mechanical endurance2 million op. cycles (std. magnetic drive)
100,000 op. cycles (latch magnetic drive)
(Replace auxiliary switch after 1,000,000 switching cycles)
Show all data

Related Downloads

Catalogue C360
C360 - AC and bi-directional DC NO contactors for 150 A, 300 A and 500 A for railway applications
Manual C360-M
Contactors C360 — Installation and Maintenance Instructions
Safety instructions contactors
AFS / C100 / C110B / C130 / C137 / C152...C159 / C160 / C162 / C163 / C164 / C165 / C193 / C195 / C294 / C295 / C160 / C3xx / C8xx / C400 / C600 / CA / CF / CH / CL / CP / CPP / CS / CT / CU / S100/80 / S132 / S134 / S135 / S005 / S007 / S008 / S306 / S307 / S310
/en/products/contactors/thank-you/C360 – DC NO contactors for railway applicationsContactors

Your quick contact to us!

If you have any questions, suggestions or other concerns, please let us know. Please fill out our short contact form.